Working software prototype

TARVATA Sentinel

Evidence-based industrial equipment investigation using simulated telemetry.

Sentinel links simulated equipment readings and configuration events to rule-based findings and records the evidence engineers can review after an intervention.

Recorded simulation · AHU-001

Investigating and restoring airflow

Simulated airflow before and after a damper-limit interventionFive samples at 10,000 CFM precede a limit reduction at 5.5 seconds. Five samples at 6,000 CFM follow. After restoration at 10.5 seconds, five samples reach the 10,000 CFM setpoint.CFM02,0004,0006,0008,00010,00012051015Elapsed time (s)

Airflow setpoint 10,000 CFM

Dots show recorded simulated airflow. The dashed horizontal line marks the setpoint.

  1. 5.5 s · Apply restrictive limit (100% → 40%)
  2. 10.5 s · Restore normal limit (40% → 100%)
  1. Baseline

    Five recorded samples matched the 10,000 CFM setpoint at a 100% damper output limit.

  2. Sustained deficit

    After the limit fell to 40%, five consecutive samples reported 6,000 CFM. Sentinel flagged the sustained deficit.

  3. Recovered in simulation

    The change event records restoration to 100%. Five subsequent samples reached 10,000 CFM, matching both the setpoint and the initial baseline. The deficit finding cleared.

View recorded samples and source
Simulated airflow samples
Time (s)Airflow (CFM)Setpoint (CFM)
110,00010,000
210,00010,000
310,00010,000
410,00010,000
510,00010,000
66,00010,000
76,00010,000
86,00010,000
96,00010,000
106,00010,000
1110,00010,000
1210,00010,000
1310,00010,000
1410,00010,000
1510,00010,000

Source snapshot 813cee90-c860-5e29-831d-29de7a10a283 (tarvata-sentinel@f1ab204 / evaluation/snapshots.json / recovery).

Physical-equipment integration and independent outcome verification remain future validation steps.

How the prototype works

  1. Ingest evidence

    The simulator sends telemetry and configuration events over MQTT. Sentinel validates and stores the messages in SQLite.

  2. Evaluate rules

    Sentinel compares samples with the airflow target and correlates findings with configuration changes in the same run.

  3. Save and explain

    A saved snapshot preserves the evidence and findings. An optional AI explanation summarizes the saved record. A local deterministic explanation is also available.

Separate replay: investigating an airflow drop after service

The prototype replays synthetic equipment readings with a simulated service record and maintenance references. The replay calculates changes in the readings and uses hypotheses and inspection steps written for this case.

  1. Symptom

    An air-handling unit reports lower airflow around the time of a filter replacement.

  2. Evidence

    Comparing the day before service with the day after shows lower average reported airflow and higher average fan power. The service record lists the replacement and leaves the filter model and installation unverified.

  3. Next verification step

    The pattern makes filter restriction worth checking. Verify the filter model and installation, then measure the pressure difference across the filter. Review damper commands and position feedback, check fan settings history, and verify airflow with an independent reading.

Discuss an equipment investigation

We welcome conversations about equipment data, intervention records, and independent measurements that could help verify physical outcomes.

Discuss an equipment investigation